Overview
The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The DT4252 is a digital multimeter designed specifically for general purpose testing, with ?0.3% DC V accuracy, direct current input and wide 40 Hz to 1kHz bandwidth.
Specifications
| DC Voltage range | 600.0 mV to 1000 V, 5 ranges Basic accuracy: ?0.3 % rdg. ?5 dgt. |
|---|---|
| AC Voltage range | 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz – 1 kHz Basic accuracy 40 – 500 Hz : ?0.9 % rdg. ?3 dgt. (True RMS, crest factor 3) |
| AUTO AC/DCV | N/A |
| Resistance range | 600.0 ? to 60.00 M?, 6 ranges, Basic accuracy: ?0.7 % rdg. ?5 dgt. |
| DC Current range | 6.000 A / 10.00 A, 2 ranges, Basic accuracy: ?0.9 % rdg. ?5 dgt. |
| AC Current range | 6.000 A / 10.00 A, 2 ranges, Basic accuracy 40 – 500 Hz : ?1.4 % rdg. ?3 dgt. (True RMS, crest factor 3, 40 Hz to 1 kHz) |
| AC Current range (use with Clamp on probes) | N/A |
| Voltage detection (50/60 Hz) | N/A |
| Capacitance range | 1.000 ?F to 10.00 mF, 5 ranges, Basic accuracy: ?1.9 % rdg. ?5 dgt. |
| Frequency range | AC V, AC A measurement: 99.99 Hz (5 Hz or more) to 9.999 kHz, 3 ranges, 99.99 kHz (only for AC V) Basic accuracy: ?0.1 % rdg. ?1 dgt. |
| Continuity check | Continuity threshold [ON]: 25 ? or less (Indicate buzzer sound, red LED), [OFF]: 245 ? or more Response time: 0.5 ms or more |
| Diode test | Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V |
| Other functions | Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option) |


Reviews