Product Code: Fluke-117-323-Kit-EUR
Brand: Fluke
Fluke117 Digital Multimeter
VoltAlert™ technology for non-contact voltage detection.
AutoVolt automatic ac/dc voltage selection.
Low input impedance: Helps prevent false readings due to ghost voltage.
Large white LED backlight to work in poorly lit areas.
True-rms for accurate measurements on non-linear loads.
Measures 10 A (20 A overload for 30-seconds).
Resistance, continuity, frequency and capacitance.
Min/Max/Average to record signal fluctuations.
Compact ergonomic design for one-handed operation.
CAT III 600 V safety rated.
Fluke 323 True-rms Clamp Meter. Rugged. Reliable. Precise.
400 A ac current measurement.
600 V ac and dc voltage measurement.
True-rms ac voltage and current for accurate measurements on non-linear signals.
Resistance measurement up to 40 k? with continuity detection.
Slim, ergonomic design.
CAT IV 300V/CAT III 600 V safety rating.
This combo kit pairs the Fluke 117 DMM with a Fluke 323 clamp meter for productive and effective troubleshooting in one total solution, including the C115 durable soft carrying case for protection and easy meter transportation.
|
Specifications |
||
|
Maximum voltage between any terminal and earth ground |
600 V |
|
|
Surge protection |
6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2 |
|
|
Fuse for A input |
11 A, 1000 V FAST Fuse (Fluke PN 803293) |
|
|
Display |
Digital: 6,000 counts, updates 4 per second |
|
|
Bar graph |
33 segments, updates 32 per second |
|
|
Operating temperature |
-10°C to +50°C |
|
|
Storage temperature |
-40°C to +60°C |
|
|
Battery type |
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
|
|
Battery life |
400 hours typical, without backlight |
|
|
Accuracy Specifications |
||
|
DC millivolts |
Range/Resolution |
600.0 mV / 0.1 mV |
|
Accuracy |
±([% of reading] + [counts]): 0.5% + 2 |
|
|
DC volts |
Range/Resolution |
6.000 V / 0.001 V |
|
Accuracy |
±([% of reading] + [counts]): 0.5% + 2 |
|
|
Auto volts |
Range/Resolution |
600.0 V / 0.1 V |
|
Accuracy |
2.0% + 3 (DC, 45 Hz to 500 Hz) |
|
|
AC millivolts¹ True RMS |
Range/Resolution |
600.0 mV / 0.1 mV |
|
Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz) |
|
|
AC volts¹ True RMS |
Range/Resolution |
6.000 V / 0.001 V |
|
Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz) |
|
|
Continuity |
Range/Resolution |
600 Ω / 1 Ω |
|
Accuracy |
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of |
|
|
Ohms |
Range/Resolution |
600.0 Ω / 0.1 Ω |
|
Accuracy |
0.9% + 1 |
|
|
Range/Resolution |
40.00 MΩ / 0.01 MΩ |
|
|
Accuracy |
5% + 2 |
|
|
Diode test |
Range/Resolution |
2.00 V / 0.001 V |
|
Accuracy |
0.9% + 2 |
|
|
Capacitance |
Range/Resolution |
1000 nF / 1 nF |
|
Accuracy |
1.9% + 2 |
|
|
Range/Resolution |
> 1000 μF |
|
|
Accuracy |
5% + 20% |
|
|
Lo-Z capacitance |
Range |
1 nF to 500 μF |
|
Accuracy |
10% + 2 typical |
|
|
AC amps True RMS (45 Hz to 500 Hz) |
Range/Resolution |
6.000 A / 0.1 A |
|
Accuracy |
1.5% + 3 |
|
|
DC amps |
Range/Resolution |
6.000 A / 0.1 A10.00 A / 0.01 A |
|
Accuracy |
1.0% + 3 |
|
|
Hz (V or A input)² |
Range/Resolution |
99.99 Hz / 0.01 Hz |
|
Accuracy |
0.1% + 2 |
|
|
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. |
||
|
Mechanical and General Specifications |
||
|
Size |
167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) |
|
|
Weight |
550 g |
|
|
Warranty |
3 years |
Fluke 323 True RMS Clamp Meter
|
Specifications |
||
|
AC current |
Range |
400.0 A |
|
Accuracy |
2% ±5 digits |
|
|
AC voltage |
Range |
600.0 V |
|
Accuracy |
1.5% ±5 digits |
|
|
DC voltage |
Range |
600.0 V |
|
Accuracy |
1.0% ±5 digits |
|
|
Resistance |
Range/Resolution |
400.0 Ω/ 4000 Ω |
|
Accuracy |
1.0% ±5 digits |
|
|
Continuity |
≤ 70 Ω |
|
|
AC response |
True RMS |
|
|
Data hold |
Yes |
|
|
Size |
H x W x D (mm) |
207 x 75 x 34 |
|
Max wire diameter |
30 mm (600 MCM) |
|
|
Weight |
265 g |
|
|
Category rating |
CAT III 600 V |
|
|
Warranty |
Two-year |

Reviews
There are no reviews yet.